4,8 RATING:
Purchase satisfaction
94,9%
Customer service
94,2%
Shop offer
93,0%

Cart

0 products
Main page > Workshop Equipment > Repair of displays (LCD) // Laminators for Polarizer/OCA > Laminator GM928 with forms for Samsung

Laminator GM928 with forms for Samsung

Laminator GM928 with forms for Samsung
Price: 1325,00 EUR w/o VAT
Unfortunately, this product is out of stock.

Click here, if you want to be notified by email when product is available

ID: 22274

Product weight: 25.00 kg

Add to store products

Ask for product

LCD and OCA laminator with forms for Samsung is used to connect curved displays with a new glass of Samsung S6 EDGE, S6 EDGE +, S7 EDGE, S8, S8 +, S9, S9 +, NOTE8 and flat displays as well as applying OCA slices on a new curved glass. The entire joining process consists in pressing the two elements together with a heated pressure press using a pressure of 3-5kg / cm2 in a vacuum. The attached forms for these Samsung phone models are used for this purpose.

Forms* for curved screens:
- Samsung S6 EDGE,
- Samsung S6 EDGE +,
- Samsung S7 EDGE,
- Samsung S8, S8 +,
- Samsung S9,
- Samsung S9 +,
- Samsung NOTE 8,
* intended for applying OCA adhesive on the display (replaces the OCA laminator) and for laminating curved screens in the laminator with simultaneous pressing of the corners. The device has a flat bottom and top surface of lamination so you can also combine all flat displays!

Specification:
- counter of laminations made,
- operating status of all solenoid valves visualized on the display,
- pressure gauges indicating LCD and OCA lamination pressure as well as vacuum values,
- S8, S8 +, S9, S9 + rubber molds have grooved holes for flex tapes - no need to bend them in the lamination process (in the pictures below - sample set for Samsung Galaxy S9).

When using GM-928, there is no need to have a separate laminator for applying OCA patches to the glass, because the GM-928 does it alone in one of the stages of the LCD screen repair process. If as a result of this process small air bubbles remain, use an autoclave available on our other auctions.

The laminator needs additionally:
- vacuum pump (manufacturer recommends target pressure -94 .. -98kPa)
- a compressor with a working pressure of 0.4-0.6 MPa (4-6 bar)
The vacuum pump and compressor are NOT INCLUDED! After connecting these two elements and setting the parameters of the laminator, it is ready for operation.

The device is very different from other similar designs on the market because for each of two lamination processes, i.e:
- connecting a curved or flat display with a new glass
- applying OCA patches to the new curved glass.
you can set separate the following parameters:
- pressure on the LCD during the lamination of the glass with the display,
- the force of pressure on the glass during lamination of the OCA adhesive with a new glass,
- lamination temperature,
- lamination time,
- operating time of the vacuum pump. / li>

Small dimensions and great capabilities of the GM928 device put it in the forefront of devices for comprehensive repairs of phone screens.

Parameters:
- power supply voltage: 220-240VAC
- power: 800W
- regulation with press force: yes 0-10 kg / cm2 (for both modes)
- information about the pressure force: yes in kg / cm2
- temperature regulation: 0-80C
- required air pressure: 0.4-0.6MPa (4-6 bar)
- required underpressure: -94 ... -98kPa
- height of the laminar chamber: 7.5 cm (for flat displays)
- width of the laminar chamber: 17cm (for flat displays)
- depth of the laminar chamber: 18cm (for flat displays)
- external dimensions: 23 [szer] x37 [depth] x41 [height] cm
- net weight: 18kg













Kit contents:
- vacuum-pressure laminator GM928
- OCA and LCD lamination kit for S6 EDGE, S6 EDGE +, S7 EDGE, S8, S8 +, S9, S9 +, NOTE8
- user manual
- polyurethane foam 160x190x6mm
Product weight: 25.00 kg.
Country:
Courier:
Delivery time: 3-7 working days
Shipping cost: 235.85 EUR

NEGOTIATE PRICE

Product placed on the market in the EU before December 13, 2024: YES



Safety Warnings and Usage Guidelines

Based on the requirements of Regulation (EU) 2023/988 on General Product Safety (GPSR), we present a list of safety warnings. The aim is to protect users from potential hazards resulting from improper use of products/devices.

1. General Safety Measures

* Use the device only in accordance with its intended purpose and the manufacturer's instructions.
* Before first use, read the user manual carefully.

Hazards for children:
* Keep the product/device out of reach of children. Children are unable to assess existing risks.

2. Mechanical Hazards

* Check that all components are properly assembled before operating the device.
* Avoid using tools that may damage the product or contribute to its damage. Do not modify the product: do not open/disassemble it!

3. Electrical Hazards
* Connect only to a socket with the appropriate voltage, in accordance with the manufacturer’s requirements.
* Improper handling of products powered by mains voltage may result in fatal electric shock! If the product and/or the connection cable are damaged, do not touch them; there is a risk of fatal electric shock! Never use the device if the power cord is damaged, frayed, or cut. Avoid touching the power cord or plug with wet hands.
* Product with a separate power supply: before connecting the device to a plug-in or external power supply, ensure that the voltage, polarity (plus/+ and minus/-), and plug dimensions (e.g., inner/outer diameter) match the device.
* Product with a mains plug: the power outlet used for connection must be located near the product and easily accessible. Always unplug the power cord by pulling the plug, not the cable.
* Product with a power cord: the power cable must not be pinched, bent, or damaged by sharp edges. Do not place any objects on the power cord or step on it. The cable should always be arranged carefully to prevent tripping.
* Product intended for soldering: use only appropriate electronic solder and an electronic soldering iron. The soldering process should be performed quickly to avoid overheating and possible damage to the product.

4. Usage Precautions

* Place the product on a stable, flat surface to prevent it from tipping over.
* Always maintain sufficient space around the device (as recommended by the manufacturer) to ensure proper ventilation.
* The operation of certain products (e.g., machines or tools) requires the use of personal protective equipment to minimize health or other risks. This includes, for example, suitable hearing protection, an appropriate respirator/dust mask, or safety goggles, as well as proper gloves, safety footwear, and clothing.

5. Maintenance and Cleaning
* Before performing maintenance or cleaning, read the product’s user manual.
* Improper cleaning agents may not only damage the product but also cause other hazards — follow the manufacturer’s guidelines.

6. User Warnings
* Elderly persons or individuals with limited mobility should exercise particular caution when operating the product and, if necessary, seek assistance from another person.
* If the device operates abnormally (e.g., emits smoke, overheats, or produces unusual sounds), immediately switch it off, disconnect it from power, and contact authorized service.
* Store the product in a dry and cool place to prevent mechanical and electrical damage.

7. Disposal
* All electrical and electronic equipment placed on the European market must be properly disposed of. This means that, at the end of its service life, the device must be disposed of separately from unsorted household waste.

8. Importance of Following the Warnings
Following the above warnings minimizes the risk of personal injury, device malfunction, and material losses. Ignoring these recommendations may lead to serious health and material hazards. Protect yourself and your loved ones by following the indicated safety measures. Detailed warnings or product safety information are available in the user manual supplied with the product or in PDF format on the manufacturer’s/supplier’s website.

 

If you are interested in Laminator GM928 with forms for Samsung you will probably want to take a look at following products:

You might also be interested in:

Automatic vacuum laminator TBK K-765 7,4 + Automatic vacuum laminator TBK K-765 7,4" more
Price:
309.00 EUR w/o VAT
Vaccum OCA laminator TBK 761 with build-in pump + Vaccum OCA laminator TBK 761 with build-in pump more
Price:
269.00 EUR w/o VAT
OCA Screen Support adapter for Remax + OCA Screen Support adapter for Remax more
Price:
15.00 EUR w/o VAT
Automatic vacuum laminator TBK763 OCA 7'' (Compressed Air version) + Automatic vacuum laminator TBK763 OCA 7'' (Compressed Air version) more
Price:
299.00 EUR w/o VAT
HONGZHUN JIDIAN FM-02 laminator 2in1 + HONGZHUN JIDIAN FM-02 laminator 2in1 more
Price:
409.00 EUR w/o VAT
UYUE X13S laminator LCD/OCA for straight and curved screens 15.1 + UYUE X13S laminator LCD/OCA for straight and curved screens 15.1" (24x30cm) more
Price:
969.00 EUR w/o VAT
Automatic vacuum laminator OCA TBK K-766 12'' + Automatic vacuum laminator OCA TBK K-766 12'' more
Price:
670.00 EUR w/o VAT
REMAX Screen Attach Machine for tablets + REMAX Screen Attach Machine for tablets more
Price:
18.00 EUR w/o VAT

Note

1. Offered by us accessories and replacement parts are not original phone producer parts, but they have been carefully choosen from list of producers to offer highest quality.

2. Our company sale only hardware/HASP/Box - not software for it. Software can be found and downloaded directly from producers webpage.

3. All trademarks mentioned on this site are property of their respective companies. Including product names, logos, commercial symbols, trade names and slogans are trademarks of those respective or related companies, and are protected by international trademark laws, and they are used here only for information purpose.