Air Ionizer Dr. Schneider SL-001 designed to neutralize static electricity. The phenomenon of electrostatic discharge leads to problems during production or service facilities such as. damage electronic circuits, clogging elements on the tapes or vibrating conveyors , adjacent foreign bodies, eg. Dust, etc. The solution to these problems are ionizers, which can completely neutralize static electricity or limit to a minimum. Fan Ionizers are designed for larger areas. Model SL-001 has a flow variable speed fan for airflow to 110CFM. The device has a mechanism for cleaning the electrodes. Ionizer very well in with a humidifier in the process of repairing damaged LCDs.

Technical data:
- Current consumption: 0,12-0,25A
- Air flow: 45-110CFM
- Operating temperature: 0-50 ° C
- Ionization area: 300x900mm
- Ion balance 0 +/- 10V
- Test voltage: 100V ~ 1000V
- Area ionization: 300mm (1,2sek), 600mm (2,5sek), 900mm (4,0sek)
- Ionisation method: unloading of a high-frequency piezoelectric
- Production of ozone: 0,03PPM
- Noise level: 49-59dB
- A mechanism for cleaning the electrodes: yes
- Dimension: 170x90x260mm
- Weight: 3kg
- Warranty: 12 months




Product weight: 3.40 kg.
Country:
Courier:
Delivery time: 3-7 working days
Shipping cost: 41.93 EUR

NEGOTIATE PRICE

Product placed on the market in the EU before December 13, 2024: YES



Safety Warnings and Usage Guidelines

Based on the requirements of Regulation (EU) 2023/988 on General Product Safety (GPSR), we present a list of safety warnings. The aim is to protect users from potential hazards resulting from improper use of products/devices.

1. General Safety Measures

* Use the device only in accordance with its intended purpose and the manufacturer's instructions.
* Before first use, read the user manual carefully.

Hazards for children:
* Keep the product/device out of reach of children. Children are unable to assess existing risks.

2. Mechanical Hazards

* Check that all components are properly assembled before operating the device.
* Avoid using tools that may damage the product or contribute to its damage. Do not modify the product: do not open/disassemble it!

3. Electrical Hazards
* Connect only to a socket with the appropriate voltage, in accordance with the manufacturer’s requirements.
* Improper handling of products powered by mains voltage may result in fatal electric shock! If the product and/or the connection cable are damaged, do not touch them; there is a risk of fatal electric shock! Never use the device if the power cord is damaged, frayed, or cut. Avoid touching the power cord or plug with wet hands.
* Product with a separate power supply: before connecting the device to a plug-in or external power supply, ensure that the voltage, polarity (plus/+ and minus/-), and plug dimensions (e.g., inner/outer diameter) match the device.
* Product with a mains plug: the power outlet used for connection must be located near the product and easily accessible. Always unplug the power cord by pulling the plug, not the cable.
* Product with a power cord: the power cable must not be pinched, bent, or damaged by sharp edges. Do not place any objects on the power cord or step on it. The cable should always be arranged carefully to prevent tripping.
* Product intended for soldering: use only appropriate electronic solder and an electronic soldering iron. The soldering process should be performed quickly to avoid overheating and possible damage to the product.

4. Usage Precautions

* Place the product on a stable, flat surface to prevent it from tipping over.
* Always maintain sufficient space around the device (as recommended by the manufacturer) to ensure proper ventilation.
* The operation of certain products (e.g., machines or tools) requires the use of personal protective equipment to minimize health or other risks. This includes, for example, suitable hearing protection, an appropriate respirator/dust mask, or safety goggles, as well as proper gloves, safety footwear, and clothing.

5. Maintenance and Cleaning
* Before performing maintenance or cleaning, read the product’s user manual.
* Improper cleaning agents may not only damage the product but also cause other hazards — follow the manufacturer’s guidelines.

6. User Warnings
* Elderly persons or individuals with limited mobility should exercise particular caution when operating the product and, if necessary, seek assistance from another person.
* If the device operates abnormally (e.g., emits smoke, overheats, or produces unusual sounds), immediately switch it off, disconnect it from power, and contact authorized service.
* Store the product in a dry and cool place to prevent mechanical and electrical damage.

7. Disposal
* All electrical and electronic equipment placed on the European market must be properly disposed of. This means that, at the end of its service life, the device must be disposed of separately from unsorted household waste.

8. Importance of Following the Warnings
Following the above warnings minimizes the risk of personal injury, device malfunction, and material losses. Ignoring these recommendations may lead to serious health and material hazards. Protect yourself and your loved ones by following the indicated safety measures. Detailed warnings or product safety information are available in the user manual supplied with the product or in PDF format on the manufacturer’s/supplier’s website.

 

If you are interested in Air Ionizer Dr. Schneider SL-001 you will probably want to take a look at following products:

You might also be interested in:

Air Ionizer TBK ST441A + Air Ionizer TBK ST441A more
Price:
105.00 EUR w/o VAT
Quick 443C Ionizer - Electrostatic discharge eliminator + Quick 443C Ionizer - Electrostatic discharge eliminator more
Price:
537.00 EUR w/o VAT
ESD Superior 2 Chair - RS-K11 ESD + ESD Superior 2 Chair - RS-K11 ESD more
Price:
490.00 EUR w/o VAT
ESD Polyurethane Stool RS-K5 ESD-A + ESD Polyurethane Stool RS-K5 ESD-A more
Price:
108.00 EUR w/o VAT
Antistatic White Knitted ESD Nylon Gloves - L + Antistatic White Knitted ESD Nylon Gloves - L more
Price:
4.50 EUR w/o VAT
ESD Workstation Mat GD510 90x90 cm + ESD Workstation Mat GD510 90x90 cm more
Price:
34.00 EUR w/o VAT
Antistatic Tweezers GTool ESD-01 + Antistatic Tweezers GTool ESD-01 more
Price:
39.00 EUR w/o VAT
ESD Stool Chair RS-K7 ESD-B + ESD Stool Chair RS-K7 ESD-B more
Price:
128.00 EUR w/o VAT

This product was bought most often with:

Set 50pcs stickers to peel the protective layers + Set 50pcs stickers to peel the protective layers more
Price:
2.00 EUR w/o VAT
XFORM LCD positioning screen mould / template for Samsung Galaxy S7 (SM-G930) + XFORM LCD positioning screen mould / template for Samsung Galaxy S7 (SM-G930) more
Price:
13.00 EUR w/o VAT
VRArm 300mm for VR-Table + VRArm 300mm for VR-Table more
Price:
80.00 EUR w/o VAT
Set of 10 ultra probes VR-073m 0,50mm/73mm to VR-Table + Set of 10 ultra probes VR-073m 0,50mm/73mm to VR-Table more
Price:
99.00 EUR w/o VAT
Set of 10 high-precision probes with movable pins VR-064 1mm / 69mm to VR-Table + Set of 10 high-precision probes with movable pins VR-064 1mm / 69mm to VR-Table more
Price:
89.00 EUR w/o VAT
Vacuum pomp Value V-i120SV + Vacuum pomp Value V-i120SV more
Price:
89.00 EUR w/o VAT
LCD Tablet Heater TBK-568 for 12.6 + LCD Tablet Heater TBK-568 for 12.6" more
Price:
92.00 EUR w/o VAT

Note

1. Offered by us accessories and replacement parts are not original phone producer parts, but they have been carefully choosen from list of producers to offer highest quality.

2. Our company sale only hardware/HASP/Box - not software for it. Software can be found and downloaded directly from producers webpage.

3. All trademarks mentioned on this site are property of their respective companies. Including product names, logos, commercial symbols, trade names and slogans are trademarks of those respective or related companies, and are protected by international trademark laws, and they are used here only for information purpose.

Reviews

The listed opinions/reviews come only from customers who have purchased a given product/service in our online store. See what they think about a given product or service

Jonizator spelnia moje oczekiwania. Wszystko zgodne z opisem. Szybka wysylka. Polecam