Main page > Workshop Equipment > Lab Power Supplies // One channel power supplies > Laboratory Power Supply PowerLab 1502T 15V/2A DC
|
![]() |
Laboratory Power Supply PowerLab 1502T 15V/2A DC
- Product description
- Delivery cost calculator
- Wholesale orders
- Files to download
- Product safety information
Features:
- Smooth adjustment of voltage and current in the full range
- Automatically converts between Constant Voltage and Constant Current mode.
- The equipment have current limiting protection point free
- Single channel output
- Short circuit and overload protection
Specification:
- Input voltage : 230V AC ±10% 50Hz
- Voltage output : 0 - 15V
- Current output : 0 - 2A
- Operating temperature : -10C - 40C
- Relative humidity < 90%
- Storage temperature : -10C - 40C
- Relative humidity < 80%
- Constant voltage state :
- Voltage stability : ≤0.01% + 2mV
- Load stability : ≤0.01% + 2mV
- Resume time : ≤100us
- Ripple noise : ≤1mVRMS (RMS)
- Temperture coefficient : ≤200PPM/C
- Constant current state :
- Current stability : ≤0.2% +3mV
- Load stability : ≤0.2% + 3mV
- Ripple noise : ≤2mARMS
- Analog display accuracy: ±2,5%
- Weight : 2kg
- Dimensions mm : 150x127x210 cm
Photo of device:

Package contains:
- power supply PowerLab 1502T
- power cable
- warranty card
Warranty
We offer 12 months warranty for this product
|
||
NEGOTIATE PRICE
Product placed on the market in the EU before December 13, 2024: YES
Safety Warnings and Usage Guidelines
Based on the requirements of Regulation (EU) 2023/988 on General Product Safety (GPSR), we present a list of safety warnings. The aim is to protect users from potential hazards resulting from improper use of products/devices.
1. General Safety Measures
* Use the device only in accordance with its intended purpose and the manufacturer's instructions.
* Before first use, read the user manual carefully.
Hazards for children:
* Keep the product/device out of reach of children. Children are unable to assess existing risks.
2. Mechanical Hazards
* Check that all components are properly assembled before operating the device.
* Avoid using tools that may damage the product or contribute to its damage. Do not modify the product: do not open/disassemble it!
3. Electrical Hazards
* Connect only to a socket with the appropriate voltage, in accordance with the manufacturer’s requirements.
* Improper handling of products powered by mains voltage may result in fatal electric shock! If the product and/or the connection cable are damaged, do not touch them; there is a risk of fatal electric shock! Never use the device if the power cord is damaged, frayed, or cut. Avoid touching the power cord or plug with wet hands.
* Product with a separate power supply: before connecting the device to a plug-in or external power supply, ensure that the voltage, polarity (plus/+ and minus/-), and plug dimensions (e.g., inner/outer diameter) match the device.
* Product with a mains plug: the power outlet used for connection must be located near the product and easily accessible. Always unplug the power cord by pulling the plug, not the cable.
* Product with a power cord: the power cable must not be pinched, bent, or damaged by sharp edges. Do not place any objects on the power cord or step on it. The cable should always be arranged carefully to prevent tripping.
* Product intended for soldering: use only appropriate electronic solder and an electronic soldering iron. The soldering process should be performed quickly to avoid overheating and possible damage to the product.
4. Usage Precautions
* Place the product on a stable, flat surface to prevent it from tipping over.
* Always maintain sufficient space around the device (as recommended by the manufacturer) to ensure proper ventilation.
* The operation of certain products (e.g., machines or tools) requires the use of personal protective equipment to minimize health or other risks. This includes, for example, suitable hearing protection, an appropriate respirator/dust mask, or safety goggles, as well as proper gloves, safety footwear, and clothing.
5. Maintenance and Cleaning
* Before performing maintenance or cleaning, read the product’s user manual.
* Improper cleaning agents may not only damage the product but also cause other hazards — follow the manufacturer’s guidelines.
6. User Warnings
* Elderly persons or individuals with limited mobility should exercise particular caution when operating the product and, if necessary, seek assistance from another person.
* If the device operates abnormally (e.g., emits smoke, overheats, or produces unusual sounds), immediately switch it off, disconnect it from power, and contact authorized service.
* Store the product in a dry and cool place to prevent mechanical and electrical damage.
7. Disposal
* All electrical and electronic equipment placed on the European market must be properly disposed of. This means that, at the end of its service life, the device must be disposed of separately from unsorted household waste.
8. Importance of Following the Warnings
Following the above warnings minimizes the risk of personal injury, device malfunction, and material losses. Ignoring these recommendations may lead to serious health and material hazards. Protect yourself and your loved ones by following the indicated safety measures. Detailed warnings or product safety information are available in the user manual supplied with the product or in PDF format on the manufacturer’s/supplier’s website.
You might also be interested in:
+
|
YIHUA 3010D III 300W/30V/10A power supply
more
|
Price:
99.00 EUR w/o VAT |
+
|
Laboratory Power Supply POWERLAB 3010D 30V/10A LED
more
|
Price:
139.00 EUR w/o VAT |
+
|
Laboratory power supply YIHUA 3005D-IV 30V/5A/150W
more
|
Price:
85.00 EUR w/o VAT |
+
|
PowerLab I-3030D DC 30V/30A LED laboratory power supply
more
|
Price:
252.00 EUR w/o VAT |
+
|
>Laboratory Power Supply PowerLab 1502D 15V/2A DC LED
more
|
Price:
29.00 EUR w/o VAT |
+
|
Laboratory Power Supply POWERLAB 302D 30V/2A DC LED
more
|
Price:
52.00 EUR w/o VAT |
+
|
I-3020D Powerlab laboratory power supply DC 30V 20A LED
more
|
Price:
135.00 EUR w/o VAT |
+
|
Laboratory Power Supply PowerLab 605D 60V/5A DC LED
more
|
Price:
106.00 EUR w/o VAT |
This product was bought most often with:
+
|
Cables for Lab Power Supply
more
|
Price:
3.00 EUR w/o VAT |
+
|
Microscope BRESSER XTL3
more
|
Price:
162.00 EUR w/o VAT |
+
|
FRP Tool Activation for OctoPus, OctoPlus, Medusa, Medusa PRO
more
|
Price:
56.27 EUR w/o VAT |
+
|
Cable Set for Lab Power Supply with USB
more
|
Price:
5.00 EUR w/o VAT |
+
|
Silicone/Liquid tape/Assembly and sealing glue B-7000
more
|
Price:
4.50 EUR w/o VAT |
+
|
Octoplus Box + Samsung activation
more
|
Price:
139.00 EUR w/o VAT |
+
|
Octoplus Huawei Tool Activation for OctoPus, OctoPlus, Medusa, Medusa PRO
more
|
Price:
80.82 EUR w/o VAT |
Note
1. Offered by us accessories and replacement parts are not original phone producer parts, but they have been carefully choosen from list of producers to offer highest quality.
2. Our company sale only hardware/HASP/Box - not software for it. Software can be found and downloaded directly from producers webpage.
3. All trademarks mentioned on this site are property of their respective companies. Including product names, logos, commercial symbols, trade names and slogans are trademarks of those respective or related companies, and are protected by international trademark laws, and they are used here only for information purpose.