|
Main page > Data Recovery > VR-TABLE // VR-Table eMMC/eMCP/JTAG ISP > VR-TABLE PRO - Dual-Side ISP/ICSP SD/MMC SPI JTAG UART FBUS USB
|
![]() |
VR-TABLE PRO - Dual-Side ISP/ICSP SD/MMC SPI JTAG UART FBUS USB
- Product description
- Delivery cost calculator
- Wholesale orders
- Files to download
- Product safety information
VR-TABLE PRO Dual-Side Platform for ISP/ICSP, SD/MMC, SPI, UART, JTAG
VR-TABLE PRO is a professional diagnostic platform designed to provide contact with test points on both sides of printed circuit boards. It supports ISP/ICSP - MPH-Y, SD/MMC, SPI, JTAG, UART, FBUS and USB workflows, enabling reading, writing, diagnostics and communication with electronic components without soldering wires directly to the board or removing the components.

Applications
Features
Designed for digital forensic laboratories, data recovery laboratories, electronics repair centres, mobile device service centres, motherboard diagnostics, automotive electronics, industrial electronics and embedded systems. It provides a stable and organised workstation that integrates with external service boxes, programmers and measuring equipment through dedicated slide-in adapters, precision arms and probes, as well as a robust construction.
Dual-Side Access to the PCB
One of the key features of VR-TABLE PRO is the ability to work on both the top and bottom sides of a mounted PCB without rotating or remounting it. The elevated dual-side design provides controlled access to test points located on both sides of the board. The PCB remains securely fixed and correctly aligned, allowing the operator to focus on probe placement and signal routing. This solution is particularly useful for complex boards where power, data, clock, reset and communication points are distributed across different sides of the PCB. Reducing the need to reposition the board also lowers the risk of probe displacement, loss of contact or mechanical damage to the electronics.

Solderless workflow
VR-TABLE PRO provides contact with PCB test points without soldering wires directly to the board. This reduces interference with the device, lowers the risk of damaging delicate pads and shortens the time required to prepare the workstation. The configuration can be easily modified, reproduced or reused when working with additional devices. This is particularly important in laboratories and service centres where process repeatability and the ability to perform extended operations without losing contact are essential.

Modular Micrometric Arms
The standard VR-TABLE PRO set includes 10 independent micrometric arms. Each arm enables precise probe positioning over a selected test point and keeps the probe stable throughout the operation. The modular design allows the arms to be arranged freely according to the size, shape and component layout of the PCB. The platform supports simultaneous work with multiple test points, including those located on compact and densely populated boards. The open working area provides convenient access to the PCB, probes and cables, while also making precise work under a microscope easier.

Stable Contact with Spring-Loaded Probes
The 3-in-1 VR-PROBE spring-loaded probes maintain even and controlled pressure on selected test points. This reduces the risk of probe movement, interrupted communication or the need to reposition the setup during extended read or write operations. The platform supports connections via SMA cables, 4 mm banana cables and FF cables. This makes it easier to integrate VR-TABLE PRO with service boxes, programmers, power supplies and measuring equipment.

Dedicated Touchscreen Power Supply Module
VR-TABLE PRO includes a dedicated power module as standard. The module has been designed for professional ISP/ICSP work with memory interfaces and for board-level access scenarios.

The module offers:
- Touchscreen control of the power line
- Fixed 3,3 V, 2,8 V and 1,8 V outputs
- Adjustable VCCQ line from 1,2 V to 3,6 V
- Real-time current monitoring
This allows the required voltages to be configured conveniently and the device’s behaviour to be monitored during operation.
Organized Diagnostic Platform
VR-TABLE PRO integrates PCB holders, arms, probes and service-box connectivity through slide-in adapters into a single platform, creating an organized and convenient workstation for everyday use. The solution is suitable for both individual repair cases and professional service centres performing a high volume of diagnostic operations.

Built-in LED Lightning
VR-TABLE PRO features integrated LED lighting that illuminates the central working area. It improves the visibility of test points and makes it easier to position probes correctly, align the PCB and perform visual inspections. The lighting is particularly useful when working under a microscope and with small, densely arranged test points. The LED lighting is powered by 18650 batteries. Batteries are not included.

Slide-in Adapters
The dedicated slide-in adapter system enables quick and organized connection of the platform to popular service boxes and programmers. The operator places the appropriate adapter in the holder, connects the power and signal cables, and then links the adapter to the selected device. There is no need to rebuild the entire connection setup from scratch for each operation.
VR-TABLE PRO is designed to work with:
- Z3X / Easy-JTAG,
- Medusa PRO
- UFI Box
- Octoplus

Dedicated Service Box Holder
The platform can be equipped with a dedicated holder designed to secure service boxes in a stable position. The holder uses the height extender’s locking screw and helps keep the workstation organized when working with devices such as Medusa PRO II or FLASH64. The service box remains securely positioned close to the PCB, making cable routing easier and reducing the risk of accidental movement during operation.
Supported Interfaces and Applications
VR-TABLE PRO has been designed around real-world workflows used in digital forensics, data recovery and advanced electronics diagnostics. The platform provides stable physical contact with PCB test points and communication lines, particularly when working with mobile devices, automotive modules, GPS units, IoT electronics and embedded systems.
How Does The Workflow Look?
-
1
Mount & align the board
Secure the PCB in the dual-side fixture and set a
stable, repeatable position. -
2
Locate test points & probe
Bring the micrometric arms to the test points and lock in clean, steady contact.
-
3
Connect your box & work
Insert a slide-in adapter and hook up Z3X / Easy-JTAG, Medusa Pro, UFI Box, FLASH64, or Octoplu
-
4
SD/MMC SPI UART JTAG
sPerform operations directly on the board through VR-TABLE PRO without soldering.
Who Is It For?
Non-invasive data acquisition where repeatability and controlled handling of the device are essential.
ISP/ICSP workflows through SD/MMC, MPH-Y and SPI, as well as board-level access through UART and JTAG, for devices requiring reliable contact.
Advanced diagnostics, board-level access and communication with supported devices without direct soldering.
A professional platform for repeatable technical operations on mobile and embedded electronics.
Work with car radios, modules, control units and communication interfaces requiring stable probe contact.
Key Benefits
- Work with PCB test points without soldering wires.
- Access to both the top and bottom sides of the PCB without remounting.
- 10 independent micrometric arms.
- 3-in-1 spring-loaded probes.
- Stable, controlled pressure on test points.
- Simultaneous contact with multiple test points.
- Integrated LED lighting.
- Support for ISP/ICSP - SD/MMC or MHP-Y, SPI, JTAG, UART, FBUS and USB.
- Dedicated slide-in adapters.
- Option to mount a service box.
- Touchscreen-controlled power module.
- Real-time current consumption monitoring.
- Brushed aluminium and TecaForm-H construction.
- Fully bearing-supported guides and holders.
- Open working area suitable for microscope work.
- Repeatable workstation setup.
-
Less improvised cabling on the workstation.
Lower Risk Than Traditional Rework
Traditional Rework
- Component removal and exposure to heat
- Slow, one-time setup that is difficult to reproduce
- Requires a dedicated rework station
- Risk of lifted pads and PCB damage
VR-TABLE PRO
- The PCB remains intact - no soldering required
- Fast, repeatable setup
- Ready for use on the workbench - first readout within minutes
- Controlled, low-risk contact
Comparison: VR-TABLE vs VR-TABLE PRO
Set Contents:
- VR-TABLE PRO main unit
- 10 modular micrometric arms
- 3-in-1 spring-loaded probes
- Slide-in adapters and power module
- Power and signal cables (30 cm)
-
Transport case
Specification:
- Dimensions: 39.5 × 32.5 × 28 cm
- Weight: 10.5 kg
- Maximum PCB size: 21 × 22 cm
- Construction: brushed aluminium and TecaForm-H
- Guides and holders: fully bearing-supported
-
Lighting: LED lighting powered by 18650 batteries
(Batteries are not included and set and must be purchased by client if needed)
Manufacturer:
Multi-COM Sp. z o.o.
|
||
NEGOTIATE PRICE
Safety Warnings and Usage Guidelines
Based on the requirements of Regulation (EU) 2023/988 on General Product Safety (GPSR), we present a list of safety warnings. The aim is to protect users from potential hazards resulting from improper use of products/devices.
1. General Safety Measures
* Use the device only in accordance with its intended purpose and the manufacturer's instructions.
* Before first use, read the user manual carefully.
Hazards for children:
* Keep the product/device out of reach of children. Children are unable to assess existing risks.
2. Mechanical Hazards
* Check that all components are properly assembled before operating the device.
* Avoid using tools that may damage the product or contribute to its damage. Do not modify the product: do not open/disassemble it!
3. Electrical Hazards
* Connect only to a socket with the appropriate voltage, in accordance with the manufacturer’s requirements.
* Improper handling of products powered by mains voltage may result in fatal electric shock! If the product and/or the connection cable are damaged, do not touch them; there is a risk of fatal electric shock! Never use the device if the power cord is damaged, frayed, or cut. Avoid touching the power cord or plug with wet hands.
* Product with a separate power supply: before connecting the device to a plug-in or external power supply, ensure that the voltage, polarity (plus/+ and minus/-), and plug dimensions (e.g., inner/outer diameter) match the device.
* Product with a mains plug: the power outlet used for connection must be located near the product and easily accessible. Always unplug the power cord by pulling the plug, not the cable.
* Product with a power cord: the power cable must not be pinched, bent, or damaged by sharp edges. Do not place any objects on the power cord or step on it. The cable should always be arranged carefully to prevent tripping.
* Product intended for soldering: use only appropriate electronic solder and an electronic soldering iron. The soldering process should be performed quickly to avoid overheating and possible damage to the product.
4. Usage Precautions
* Place the product on a stable, flat surface to prevent it from tipping over.
* Always maintain sufficient space around the device (as recommended by the manufacturer) to ensure proper ventilation.
* The operation of certain products (e.g., machines or tools) requires the use of personal protective equipment to minimize health or other risks. This includes, for example, suitable hearing protection, an appropriate respirator/dust mask, or safety goggles, as well as proper gloves, safety footwear, and clothing.
5. Maintenance and Cleaning
* Before performing maintenance or cleaning, read the product’s user manual.
* Improper cleaning agents may not only damage the product but also cause other hazards — follow the manufacturer’s guidelines.
6. User Warnings
* Elderly persons or individuals with limited mobility should exercise particular caution when operating the product and, if necessary, seek assistance from another person.
* If the device operates abnormally (e.g., emits smoke, overheats, or produces unusual sounds), immediately switch it off, disconnect it from power, and contact authorized service.
* Store the product in a dry and cool place to prevent mechanical and electrical damage.
7. Disposal
* All electrical and electronic equipment placed on the European market must be properly disposed of. This means that, at the end of its service life, the device must be disposed of separately from unsorted household waste.
8. Importance of Following the Warnings
Following the above warnings minimizes the risk of personal injury, device malfunction, and material losses. Ignoring these recommendations may lead to serious health and material hazards. Protect yourself and your loved ones by following the indicated safety measures. Detailed warnings or product safety information are available in the user manual supplied with the product or in PDF format on the manufacturer’s/supplier’s website.
You might also be interested in:
+
|
VR-TABLE for JTAG EMMC FBUS Tool
more
|
Price:
1199.00 EUR w/o VAT |
+
|
Universal PullUp PU eMMC cable for VR-Table (VR64)
more
|
Price:
20.00 EUR w/o VAT |
+
|
Set of Universal JTAG adapters VF-JIG for VR-Table - 11R
more
|
Price:
219.00 EUR w/o VAT |
+
|
Inspection camera RF for VR-Table - 4K with holder
more
|
Price:
269.00 EUR w/o VAT |
+
|
VRArm 300mm for VR-Table
more
|
Price:
80.00 EUR w/o VAT |
+
|
Inspection camera for VR-Table - VGA 2Mpx with holder
more
|
Price:
229.00 EUR w/o VAT |
+
|
Holder for inspection camera used in VR-Table
more
|
Price:
50.00 EUR w/o VAT |
Note
1. Offered by us accessories and replacement parts are not original phone producer parts, but they have been carefully choosen from list of producers to offer highest quality.
2. Our company sale only hardware/HASP/Box - not software for it. Software can be found and downloaded directly from producers webpage.
3. All trademarks mentioned on this site are property of their respective companies. Including product names, logos, commercial symbols, trade names and slogans are trademarks of those respective or related companies, and are protected by international trademark laws, and they are used here only for information purpose.














